FKN-H Fusible Wire Wound Resistors Over Current Protection
  • FKN-H Fusible Wire Wound Resistors Over Current ProtectionFKN-H Fusible Wire Wound Resistors Over Current Protection

FKN-H Fusible Wire Wound Resistors Over Current Protection

FKN-H Fusible Wire Wound Resistors Over Current Protection Features: 1. Fusing current and fusing time can be consulted between buyers and the manufacturer before producing. 2. Noncombustible insulating coating;“Solvent” proof and resistant to high temperature. 3. Uniform in fusing time. 4. Excellent anti-surge characteristics according to IEC 61000-4-5. 5. Suitable for the application to half short-circuit of a charger.

Send Inquiry

Product Description

FKN-H Fusible Wire Wound Resistors Over Current Protection



Products

FKN-H Fusible Wire Wound Resistors Over Current Protection

Features

1. Fusing current and fusing time can be consulted between buyers and the manufacturer before producing.

2. Noncombustible insulating coating;“Solvent” proof and resistant to high temperature.

3. Uniform in fusing time.

4. Excellent anti-surge characteristics according to IEC 61000-4-5.

5. Suitable for the application to half short-circuit of a charger.




Electrical And Mechanical Performance of FKN-H Fusible Wire Wound Resistors Over Current Protection: 


Characteristics

Standards

Test Methods

Resistance Tolerance

±5%(J)

 

-

Resistance Temp. Coeff.

<4500 ppm/°C

 

-55°C ~200°C

 

Power Rating Load

Surface temp.275°C Max.ΔR/R≤±2%

Rated voltage for 30 minutes

Short Time Overioad

±2%

10times of rated wattage for 5 seconds.

Dielectric Withstanding Voltage

No evidence of mechanical damage or insulation breakdown.

 

AC 350V for 1 minutes

 

Insulation Resistance

10,00MΩ

DC 100V megger

 

Fusing Characteristics

 

Fusing time is within 60 seconds.

 

25 times of rated wattage

 

Solder-ability

Minimum95%coverage

235 ± 5°C for 2 seconds

Resistance to Soldering Heat

No evidence of mechanical damage.ΔR/R≤±1%

270±5°C for 10 ±1 seconds

350±10°C for3.5 ±0.5 seconds




Environmental Characteristics of FKN-H Fusible Wire Wound Resistors Over Current Protection:


Characteristics

Standards

Test Methods

Temp. Cycle

△R/R≤±1%

 -55°C( 30 min.) —►Room Temp.( 3 min.) —► +200°C( 30 min.)

 —► Room Tenp.( 3 min.) / ( 5 cycles)

Load Life

△R/R≤±5%

Rated power load 90 minutes ON 30 minutes OFF

70°C 1000 hours

Moisture-proof Load Life

△R/R≤±5%

Rated power load 90 minutes ON 30 minutes OFF

40°C95%RH1000 hours

Nonflammability

 

not flamed

 

16 times of rated wattage for 5 min.

 




Dimensions of FKN-H Fusible Wire Wound Resistors Over Current Protection:


 

Rated

 

Wattage

D

L±1

H±3

d±0.1

Resistance Range(Ω)

1W

3.5 Max.

 

9

28

0.65

1~20

 






Derating Curve of FKN-H Fusible Wire Wound Resistors Over Current Protection:


For resistors operated in ambient temperatures above20°C , power rating must be derated in accordance with the curve below.


FKN-H Fusible Wire Wound Resistors Over Current Protection factory




Surface Temperature Rise of FKN-H Fusible Wire Wound Resistors Over Current Protection:

 FKN-H Fusible Wire Wound Resistors Over Current Protection data





Hot Tags: FKN-H Fusible Wire Wound Resistors Over Current Protection, China, Manufacturer, Supplier, Factory, Wholesale, Cheap, Made in China, Free sample