The following is about Plate Cement Resistors BK related, I hope to help you better understand Plate Cement Resistor(BK-2).
Plate Cement Resistors BK
Specifications and Dimensions of Plate Cement Resistors BK:
Part No. | Power | Dimensions(mm) | Resistance range | ||||||
L±1 | H±1 | P±1 | d±0.1 | D±0.2 | W±1 | HXR | NRX | ||
RXR05B(HRX/NRX) | 5W | 41 | 11 | 33 | 0.8 | 2.0 | 28 | 1K~100K | 0R2~39R |
Electricity Performance Parameters of Plate Cement Resistors BK:
Power | Electricity Performance Parameters | ||
Max. | Max. | With-stand | |
1W | 15OV | 300V | 500V |
2W | 150V | 500V | 1000V |
3W | 350V | 600V | 1000V |
5W | 350V | 600V | 1000V |
7W | 500V | 700V | 1000V |
10W | 500V | 800V | 1000V |
1OW | 750V | 850V | 1000V |
15W | 1000V | 1000V | 1000V |
20W | 1000V | 1000V | 1500V |
25W | 1000V | 1000V | 1500V |
30W | 1000V | 1000V | 1500V |
40W | 1000V | 1000V | 1500V |
50W | 1200V | 1000V | 1700V |
80W | 1400V | 1000V | 2000V |
100W | 1500V | 1000V | 2200V |
Performance Test of Plate Cement Resistors BK:
Test Item | Test Condition | Performance |
Temperature Coefficient | The resistance value at normal temperature and normal temperature added 100°C, calculate per °C resistance value change rate. | ±300ppm/°C |
Short Time overload | According 10 times rated power to account the voltage or max .overload voltage (get the lower) for 5 seconds. | R≤±(2%+0.05Ω) |
Resistance to soldering Heat | Immerge into the 350±10°C tin stove for 2~3seconds. | R≤±(1%+0.05Ω) |
Solderability | Immerge into the 235±3°C tin stove for 2~3seconds. | The soldering area is over95% |
Temperature cycling | At -55°C for 30 min. ,then at+25°C for 10~15°C,then at +155°C for 30 min., then at +25°C for 10~15 min., total 5cycles. |
R≤±(1%+0.05Ω) |
Load life in humidity | Overload rated voltage or Max. working voltage(get the lower) for 1000 hours(1.5hours on and hours off) at the 40±2°C and 90~95% relative humidity. |
R≤±(5%+0.05Ω) |
Load life in heat | Overload rated voltage or Max. working voltage(get the lower) for 1000 hours(1.5hours on and hours off) at the 70±2°C. |
R≤±(5%+0.05Ω) |
Terminal strength | Pull :10N | R≤±(2%+0.1Ω) |
Vibration | Frequency :10~55Hz. | R≤±(2%+0.1Ω) |
Nonflammability | Respectively load AC voltage by5,10,16times rated power for 5 minutes. | No visible flame |
Rated Power Derating Curve: